Connector Basics:
Connector Degradation Mechanisms—Corrosion Part II
By
Robert S. Mroczkowski, Sc.D
Bishop & Associates Inc.
This is the third
article in a series on connector degradation mechanisms and the second
article focused on corrosion. Tin-to-tin contact interfaces and fretting
corrosion, as the dominant degradation mechanism in such systems, was
the focus of the previous article.
Click here
to review that article. Now, we will address corrosion effects on
contact resistance in noble metal contact systems, particularly
gold-plated interfaces. The key point in this article is the importance
of a nickel underplate beneath the gold and its benefits in enhancing
the performance of gold-plated connectors with respect to corrosion
degradation. The following paragraph is repeated from the previous
article for convenience, because it provides necessary background to
understand the kinetics of corrosion-related degradation.
In the
first article,
the asperity, or a-spot, model of a contact interface was introduced.
Figures 1 and 2 of the first article are shown for convenience in the
following discussion. The key point of the asperity model is that the
asperity contact points are very small, on the order of microns in
diameter, and are distributed across an apparent contact area determined
by the geometry of the contact springs at the interface, and the contact
force exerted by the springs due to their deflection on mating. The
electrical current across the contact interface must flow through the
asperity contact points, resulting in a resistance called constriction
resistance. The magnitude of the constriction resistance depends on the
number, size, and distribution of the asperity contacts at the
interface, because all the asperity contacts are electrically in
parallel. Constriction resistance exists even in the ideal case when all
the asperity contact interfaces are metal-to-metal, e.g. gold-to-gold or
tin-to-tin. If any of the asperity interfaces are compromised by
corrosion films or contaminants, the constriction resistance will
increase. This is the reason why corrosion is a degradation mechanism
for connectors. Loss of asperity contact area, or of asperity contacts,
due to corrosion or contamination, can result in contact interface
resistance increases sufficient to lead to connector failures.

Now, let’s move onto
corrosion degradation in gold-plated connectors. It is well known that
gold is a noble metal. That is, a metal that does not corrode, a
characteristic that accounts for the widespread use of gold in jewelry.
While that is a true statement, it does not mean that gold-plated
connectors are not susceptible to corrosion. Connectors are an
electromechanical system. They perform an electrical function, to
provide electrical continuity between two subsystems through a
mechanical spring system, which provides the desired mating and contact
force characteristics. In the case of gold-plated connectors, the system
consists of the gold surface plating and a nickel underplate (to
optimize the contacting surface) over a copper alloy spring material.
The copper alloy spring material provides the necessary spring
characteristics on connector mating. The corrosion source in this system
is the copper alloy spring material. Copper reacts with oxygen, sulfur,
and chlorine, common components of application environments where
connectors are used. So, with respect to corrosion susceptibility,
connector design must address how to eliminate, or reduce copper
corrosion, and ensure that any corrosion products that do form
cannot reach the connector contact interface. This is easy in principle,
but a challenge in practice, as we shall see.
If connector manufacturers had the luxury of completely plating the
contact springs with, say, five microns of gold, corrosion would not be
an issue in connectors. Cost effectiveness, however, dictates much
thinner platings—0.25 to 0.75 microns are typical, with the platings
being applied only at the contact interface itself, selective plating.
Meeting this economic requirement introduces two potential sources of
exposed copper spring material. Selective plating, as well as other
manufacturing processes, may lead to bare copper and bare copper edges.
Thin platings lead to potential copper exposure where defects exist in
the gold plating. In addition to these intrinsic corrosion sources, wear
of the gold plating during the mating cycles of the connector, or
disturbances of the contact interface during application, must be taken
into consideration. All of these issues are addressed by an often
overlooked and underappreciated component of the gold connector system,
the nickel underplate.

Consider first the
intrinsic issues, starting with plating thickness. Figure 2
schematically illustrates gold-plated surfaces with and without a nickel
underplate. Any defect in the gold-only plating will result in exposure
of the copper alloy spring material. Plating defects include porosity,
scratches, and incomplete surface coverage due to contaminants on the
base metal prior to plating, among others. The potential for all of
these defects is increased as plating thickness decreases. Given the
presence of such plating defects, any exposed copper alloy will react
with the application environment and the corrosion products formed can
make their way to the surface of the plating. For the purposes of this
discussion, I will simply note that copper-sulfur corrosion products are
known to migrate, or creep, over metal surfaces as indicated in Figures
2 and 3. Figure 2 schematically indicates the migration of corrosion
products up the walls of the pore site to the surface. Figure 3 is a
photomicrograph of corrosion migration rings on the surface of a
gold-plated copper alloy coupon. If the contact interface incorporated
any of the corrosion product rings indicated in Figure 3, the interface
resistance would most likely be compromised to some degree. Use of a
nickel underplate, however, both inhibits corrosion and reduces
corrosion creep. Nickel forms a very thin self-limiting and passivating
oxide that does not migrate. In effect, the nickel passivates the base
of the defect site so no corrosion products are able to migrate to the
surface.

An additional
thickness-related benefit of nickel underplates is as a diffusion
barrier. Copper diffuses readily through gold, and if diffused copper
reaches the surface of the gold-plating, it will form corrosion films on
the surface that may impede the desired metal-to-metal contact interface
that the gold surface was intended to provide. The rate of diffusion of
copper through the nickel underplate is much slower, and the nickel
underplate is typically much thicker than the gold-plating, so there is
a significant reduction in the rate of copper diffusion to the gold
surface. Because diffusion rates increase with temperature, this nickel
benefit is, of course, much more important if the connector is intended
for higher temperature applications.
The passivating and migration inhibiting characteristics of nickel are
also beneficial with respect to selective plating. If the copper alloy
spring material is plated overall with nickel, prior to selective
gold-plating of the contact interface, surface and edge corrosion (and
the associated corrosion creep to the contact interface) will be
minimized.
In addition to these intrinsic issues, the potential corrosion effects
of wear on the plating are also moderated by characteristics of the
nickel underplate. As mentioned, wear-through can occur due to the
mating cycles of the connector or through micromotions of the contact
interface due to mechanical or thermal expansion driving forces. There
are two nickel benefits to minimize wear-through as a potential
degradation mechanism. The first is the passivation and migration
inhibition characteristic of nickel as previously discussed.
Wear-through of the gold and exposure of the nickel underplate does not
lead to corrosion-related degradation. It is possible, however, that the
exposed nickel may not be as effective a metal-to-metal contact
interface as gold-to-gold, so an increased contact resistance may
result. The magnitude of such an increase would be far less than what
would occur due to corrosion effects. The second benefit provided by a
nickel underplate with respect to wear-through is an improvement in the
wear resistance of the contact plating. Wear behavior will be discussed
in more detail in the next installment of this series, so for now, it is
sufficient to note that the nickel underplate will increase the
effective hardness of the contact plating. The gold platings used on
connectors are typically so-called hard golds and have Knoop hardness of
the order of 200. Nickel underplate hardnesses are generally 400 Knoop
or higher. Thus, the effective hardness of the plating is increased and
wear rates tend to decrease as the surface hardness increases.
Given the importance of the benefits of a nickel underplate to connector
performance, what nickel thickness is necessary? A typical range of
nickel thickness in gold-plated connectors is in the range of 1.25 to
4.0 microns. The lower limit is to ensure sufficient thickness to
provide the basic benefits described. The upper limit is determined by
both cost-benefit and mechanical considerations. The cost-benefit issue
is obvious, more nickel means more plating time and material cost. The
mechanical considerations are more complicated. As nickel plating
thicknesses increase, the ductility of the nickel tends to decrease and
the roughness of the plating tends to increase. Reduced ductility can
lead to cracking of the plating, and increased roughness to compromised
porosity and wear performance.
In summary, the importance of a nickel underplate in gold-plated
connector systems cannot be overemphasized. The passivating
characteristic of nickel is significant in moderating the formation and
migration of corrosion products arising from any exposed copper surface
on the contact spring. In addition, nickel provides a diffusion barrier
against base metal constituents of the contact spring. The hardness of
nickel is important in improving the wear resistance of gold-plated
contact systems to improve both the mating cycle life of connectors and
resistance to fretting wear. Given these benefits, a nickel underplate
should always be specified for any gold-plated connector system.
 |
Dr. Robert S. Mroczkowski
Director Technology, Bishop and Associates Inc.
In 1998, Dr. Mroczkowski founded connNtext associates, a
firm providing consulting services in connector applications
to the electronics industry. Dr. Mroczkowski has over 30
years experience in various aspects of the electronics
industry. He joined AMP Inc. in 1971. While at AMP, his
responsibilities included consulting on connector design,
materials, and reliability concerns within AMP, and
providing an interface to AMP customers on the same issues.
In 1990 he joined the AMP Advanced Development Laboratories,
where he was responsible for the development of microstrip
cable connectors and a new microcoaxial connector for
medical ultrasound diagnostic equipment. Dr. Mroczkowski
retired in 1998 as an AMP principal. He is the author of the
McGraw Hill Electronics Connector Handbook, has
contributed chapters on connectors and interconnections to a
number of packaging handbooks, and written more than 20
technical papers. He holds seven patents. In 1997, Dr.
Mroczkowski received the Lifetime Achievement Award of the
International Institute of Connector and Interconnection
Technology.
He holds a bachelor’s, master’s, and doctorate of
science degrees in physical metallurgy from the
Massachusetts Institute of Technology.
|
|