By Dr. Robert S. Mroczkowski, Bishop & Associates Inc.
In the first article in this series on
connector testing, I stated that a test is a combination of
conditioning/exposures and measurements. All test sequences begin with a
measurement to establish the baseline for the parameter of interest,
e.g. electrical resistance, prior to a conditioning or an exposure
intended to simulate some field condition or degradation mechanism, e.g.
durability cycling followed by mechanical shock. Before beginning a
discussion of the test groups in the generic test plan described in the
first article, it seems reasonable to discuss the measurements that are
required in the groups. This article will discuss electrical resistance
measurements as used in the first test group.
Electrical resistance is the most common measurement in connector
testing. This is reasonable because an increase in connector resistance
is a dominant failure mode in connectors. Before discussing electrical
resistance measurement procedures, a brief discussion of the basics of
connector resistance is in order.

The figure contains a schematic
illustration of a connector contact system with the various resistance
components indicated. The overall connector resistance, RO,
is the resistance between a contact probe on the conductor as it enters
the crimped connection and the appropriate pad on the printed wiring
board plated through-hole containing the compliant pin press-in contact.
RO is the sum of five individual resistance contributions, RPC,
the permanent connection resistances of the crimped and compliant pin
terminations, RBULK, the bulk resistance of the receptacle
and pin contacts, and RC, the resistance of the separable
interface. Although two contacts are indicated at the separable
interface, the individual components are difficult to separate and a
single value for the contact interface resistance is indicated. In a
typical signal connector contact system, the magnitude of these
resistances will be of the order of a milliohm for the contact interface
resistance, several milliohms for the bulk resistances, and a fraction
of a milliohm for the permanent connections. For a typical power contact
system, all of these resistances will have a lower magnitude, with the
bulk resistances decreasing greater proportionally than the permanent
connection and contact resistances. This is due to the fact that power
contacts are generally physically larger—reducing permanent connection
and bulk resistance—and use higher contact force, therefore, reducing
the contact interface resistance.
As noted, electrical resistance measurements measure the overall contact
system resistance. The relative stability of these resistance
contributions merits attention. The bulk resistances are essentially
constant because they depend only on the resistivity of the contact
spring material and the geometry of the contact design. The stability of
the permanent connections is higher than that of the contact interface
resistance because permanent connections are not limited by separability
requirements that limit the contact force for both mating durability and
mating force reasons. Thus, the contact area in permanent connections is
greater than that in separable interfaces because more force and
deformation can be allowed. With the increased area comes a larger
number of individual contact areas, a-spots, and, thus, a-spot
redundancy. Contact area redundancy is always a benefit with respect to
resistance stability. Secondly, the residual forces that can be realized
in permanent connections are typically more robust than those of
separable interfaces. Therefore, in most cases, variations in the
overall resistance of a connector, after the conditioning and exposures
of a testing program, result from increases in the separable interface
component of connector resistance.
There are two basic types of electrical resistance measurements, Low
Level Contact Resistance (LLCR, EIA 364D, TP23) and Contact Resistance
at Rated Current (CRRC, EIA 364D, TP6). LLCR is generally specified in
the testing of signal connectors. In some cases, often a legacy
document, CRRC is specified and in some cases, both may be required.
The two measurement procedures differ in their electrical parameters.
LLCR measurements are made with an open circuit voltage limited to 20
millivolts. The test current is often 100 mA. The purpose of the low
open circuit voltage is to ensure that there is no electrical breakdown
of any surface films, oxide films, or contaminants for example, as a
result of the measurement. Under these low-level voltage conditions, the
measured resistance is that of a metal-to-metal contact interface, which
is the design goal for a connector contact interface. CRRC measurements,
in contrast, are constant current, the current rating of the contact
system without any limitation on voltage. Under these conditions, films
and contaminants may be electrically disrupted by the uncontrolled test
voltage applied to the sample. Therefore, if the test program requires
both electrical measurements, for example in power connector testing,
the LLCR measurement must always precede the CRRC measurement. The
resistances measured by these two methods will be different. CRRC
resistances will be larger than LLCR values. The resistance increase, in
the absence of any surface effects, is due to the Joule heating that
takes place at the rated current of the connector, as compared to the
100 mA specified for LLCR. Joule heating increases the temperature of
the contacts and, therefore, the resistance of the contact spring
materials. The difference in resistance observed will depend on the
current and the magnitude of the contact spring bulk resistances
included in the measurement system.

It has been noted that the measured
connector resistance includes bulk, contact interface, and termination
resistances. For completeness, a resistance measurement technique, a
“crossed rod” configuration, that measures only contact interface
resistance will be described. The terminology “crossed rod” is clear
from the figure. The significance of this configuration is that the only
common point for both the voltage and the current paths is the
intersection of the two rods. Therefore the measurement includes only
the resistance of the contact interface itself. This configuration is
generally not possible to realize in measurements on contact pairs. It
can be used, however, to eliminate the resistance contributions of
lead-in wires in the measurement system.
In the next article in this series, Max Peel, Senior Fellow of Contech
Research, will discuss some practical issues in electrical resistance
testing.
Send your comments and questions to AskDrBob@connectorsupplier.com.
 |
Dr. Robert S. Mroczkowski
Director Technology, Bishop and Associates Inc.
In 1998, Dr. Mroczkowski founded connNtext associates, a
firm providing consulting services in connector applications
to the electronics industry. Dr. Mroczkowski has over 30
years experience in various aspects of the electronics
industry. He joined AMP Inc. in 1971. While at AMP, his
responsibilities included consulting on connector design,
materials, and reliability concerns within AMP, and
providing an interface to AMP customers on the same issues.
In 1990 he joined the AMP Advanced Development Laboratories,
where he was responsible for the development of microstrip
cable connectors and a new microcoaxial connector for
medical ultrasound diagnostic equipment. Dr. Mroczkowski
retired in 1998 as an AMP principal. He is the author of the
McGraw Hill Electronics Connector Handbook, has
contributed chapters on connectors and interconnections to a
number of packaging handbooks, and written more than 20
technical papers. He holds seven patents. In 1997, Dr.
Mroczkowski received the Lifetime Achievement Award of the
International Institute of Connector and Interconnection
Technology.
He holds a bachelor’s, master’s, and doctorate of
science degrees in physical metallurgy from the
Massachusetts Institute of Technology.
|
|