Shock, Rattle, and Vibrate with the EIA
364D: Group 1 Test
By Dr.
Robert S. Mroczkowski, Bishop & Associates Inc.
This article will
begin the discussion of the generic test groups identified in EIA 364D:
Electrical Connector/Socket Test Procedures Including Environmental
Classifications. For reference, you can find the 364D generic test
program in the first article in this series, “The How and Why of
Connector Testing Programs.” The discussion begins with the first test
group, which consists of the following phases:
Electrical Resistance - Shock - Vibration -
Electrical Resistance.
This is the shortest
test group in the generic program, but it provides a good springboard
for preliminary discussion of an important aspect of connector testing
philosophy.
The test group begins with an electrical resistance measurement to
establish a base-line. which evaluates any contact resistance
degradation that may occur due to the test exposures, shock, and
vibration. The most commonly used electrical resistance measurement
procedure is LLCR (Low Level Contact Resistance, Test Procedure 23,
TP23), as discussed in a previous article in this series, “Measure Twice
and Test Once,” although TP6, contact resistance at rated current (CRAC),
is also allowed. The test group ends with an electrical resistance
measurement to quantify any change in contact resistance as a result of
the exposures of the test. If LLCR is used,
DR,
initial resistance minus end of test resistance, is the criterion. If
CRAC is used, a MVD criterion will be applied, either a change in MVD or
a maximum MVD criterion could be applied.
The electrical resistance aspects of test group 1 are straightforward,
with the exception of relating
DR
or MVD to degradation levels that affect performance in the field. We
will visit that issue in a later article.
Consider now the exposures, shock, and vibration that occur during a
test, beginning with shock. This article will only comment generally on
the exposures—details of the procedures will be discussed by Max Peel in
the following article in this series. This first test group is
essentially a screening test for the mechanical stability of the
connector. It is well known, as discussed in the Connector Degradation
series, that motion of the contact interface can be a driving force for
several degradation mechanisms. These include fretting corrosion
(primarily in tin-finished connectors), wear of the contact interface
(all finish systems), and increased sensitivity to contamination
(corrosion and particulates) around the contact interface. A connector
system that has a high degree of mechanical stability will provide more
stable performance in the field. Thus, the verification of mechanical
stability is an important part of any connector assessment test program.
The generic test program in 364D does not specify a TP for shock, but
the most commonly used is TP27, mechanical shock. The details of the
exposure, in terms of excitation format, G level, duration, etc., are
specified in TP27. For the purposes of this article, the main point is
that the conditions specified in TP27 do not correlate to application
conditions for connectors in the field. In fact, the TP27 conditions
were selected to represent shipping conditions. It should be noted that
there are other procedures for shock exposures. These include TP32,
thermal shock (temperature cycling), and drop testing, which has no TP
in 364D at this time.
The situation is similar with respect to vibration. No TP is specified
in 364D, but TP28 is the most commonly used. TP28 contains a number of
different exposure conditions with variations in excitation (sine or
random), G levels, duration (time or cycles), and axis of vibration.
Once again, these exposures do not correlate with application field
conditions.
Both TP27 and TP28 were initially mil/spec exposures that have been
carried over and applied to more generic application conditions of
electrical connectors, as they are used today. The value of these
exposures and TPs is primarily legacy and comparative. These exposures
have revealed weaknesses in connectors, and connectors that have passed
these exposures have had “acceptable” field histories. Thus, they have
their uses in assessing connectors. In “The How and Why of Connector
Testing Programs,” we discussed several reasons for testing connectors.
They include:
The information
derived from test group 1 is fully relevant to the first two purposes,
though these exposures may be used in the latter two as well. The
relevance of test group 1, to design verification and
qualification/specification testing, is that these two are, loosely
speaking, in the category of “go/no-go” test programs, and are in large
measure comparative in nature and, therefore, the data can be leveraged
against the known field performance history mentioned previously. The
relevance of such qualitative field history to performance verification
and reliability assessment is less significant. As mentioned in “How and
Why,” performance verification and reliability assessment programs
require knowledge of a more specific relationship between field
degradation driving forces, the analog to exposures in a testing
program, in order to enable some level of quantitative evaluation of
connector degradation. The use of shock and vibration in such testing
programs remains qualitative, and is primarily a legacy/comfort level
validation because of the knowledge that mechanical stability is a
significant factor in connector performance and reliability in the
field.
In the next article in this series on connector testing programs, Max
Peel will provide his insights into the implementation and selection of
test procedures, and the relevance of the test results to connector
evaluation.
Send your comments and questions to
AskDrBob@connectorsupplier.com.
 |
Dr. Robert S. Mroczkowski
Director Technology, Bishop and Associates Inc.
In 1998, Dr. Mroczkowski founded connNtext associates, a
firm providing consulting services in connector applications
to the electronics industry. Dr. Mroczkowski has over 30
years experience in various aspects of the electronics
industry. He joined AMP Inc. in 1971. While at AMP, his
responsibilities included consulting on connector design,
materials, and reliability concerns within AMP, and
providing an interface to AMP customers on the same issues.
In 1990 he joined the AMP Advanced Development Laboratories,
where he was responsible for the development of microstrip
cable connectors and a new microcoaxial connector for
medical ultrasound diagnostic equipment. Dr. Mroczkowski
retired in 1998 as an AMP principal. He is the author of the
McGraw Hill Electronics Connector Handbook, has
contributed chapters on connectors and interconnections to a
number of packaging handbooks, and written more than 20
technical papers. He holds seven patents. In 1997, Dr.
Mroczkowski received the Lifetime Achievement Award of the
International Institute of Connector and Interconnection
Technology.
He holds a bachelor’s, master’s, and doctorate of
science degrees in physical metallurgy from the
Massachusetts Institute of Technology.
|
|